{"id":14421,"date":"2024-01-17T16:54:55","date_gmt":"2024-01-17T15:54:55","guid":{"rendered":"https:\/\/faveker.com\/consejos-antes-rehabilitacion-fachadas\/"},"modified":"2026-08-28T11:00:23","modified_gmt":"2026-08-28T09:00:23","slug":"tips-before-facade-renovation","status":"publish","type":"post","link":"https:\/\/faveker.com\/en\/blog\/tips-before-facade-renovation\/","title":{"rendered":"The Impact of Extreme Weather on Buildings: A Renovation Guide to Protect and Add Value to Homes"},"content":{"rendered":"<p>[vc_row][vc_column]<style>.ld_spacer_6aa7742e9d5ce{height:22px;}<\/style>\n<div class=\"ld-empty-space ld_spacer_6aa7742e9d5ce\"><\/div>[vc_column_text]Today\u2019s residential and commercial building stock faces an unprecedented challenge. For the most part, these structures were designed for a much milder and more predictable climate. Today, an <strong>aging building stock<\/strong> is colliding head-on with the reality of increasingly extreme weather. Prolonged heatwaves, intense storms, dramatic temperature fluctuations and harsh coastal conditions are accelerating the deterioration of building envelopes.<\/p>\n<p>Against this backdrop, traditional, <strong>reactive fa\u00e7ade maintenance<\/strong>\u2014such as patching, painting and resealing\u2014is no longer enough. Protecting and increasing the value of our built heritage requires us to rethink the building envelope entirely. In this guide, we explore <strong>how extreme weather affects buildings<\/strong> and why <a href=\"https:\/\/faveker.com\/en\/renovation\/\"><strong>renovating<\/strong><\/a> with a <a href=\"https:\/\/faveker.com\/en\/ventilated-facade\/\"><strong>ceramic ventilated fa\u00e7ade<\/strong><\/a> has established itself as the definitive architectural solution for specifiers and building owners alike.[\/vc_column_text]<style>.ld_spacer_6aa7742e9d7ee{height:15px;}<\/style>\n<div class=\"ld-empty-space ld_spacer_6aa7742e9d7ee\"><\/div>[vc_column_text]<\/p>\n<h2>The Invisible Problem: Aging Residential Building Stock and Climate Vulnerability<\/h2>\n<p>[\/vc_column_text]<style>.ld_spacer_6aa7742e9d8e1{height:15px;}<\/style>\n<div class=\"ld-empty-space ld_spacer_6aa7742e9d8e1\"><\/div>[vc_column_text]To understand the scale of today\u2019s challenge, we must examine the structural starting point. A large portion of the building stock constructed during the <strong>1960s, 1970s and early 1980s<\/strong> was built during a period of rapid demographic growth, but with a notable <strong>lack of energy-efficiency and thermal-protection regulations<\/strong>. In Spain, for example, it was not until the NBE-CT-79 standard came into force that minimum insulation requirements began to be mandated for buildings.<\/p>\n<p>As a result, millions of <strong>homes, public buildings and corporate properties<\/strong> today feature basic wall assemblies, exposed brick fa\u00e7ades lacking insulated cavities or continuous render finishes that absorb the weather without any buffering capacity. These buildings were energy-inefficient from day one, but today they are also extremely vulnerable to climate change.<\/p>\n<p>The increasing frequency of <strong>severe weather events<\/strong> is accelerating thermal fatigue in traditional materials. Fa\u00e7ades are subjected to far more pronounced <strong>expansion and contraction cycles<\/strong> than they were decades ago; wind-driven rain impacts surfaces with greater force, and high levels of ultraviolet radiation rapidly degrade exterior finishes.<\/p>\n<table style=\"height: 67px;\" width=\"1250\">\n<tbody>\n<tr>\n<td width=\"547\">\ud83d\udd17 <em>This structural aging not only compromises safety, but also drives up energy consumption due to an increased reliance on heating and air conditioning. To learn more about optimizing resources, read our article: <\/em><a href=\"https:\/\/faveker.com\/en\/blog\/energy-rehabilitation-building\/\"><strong><em>Energy-Efficient Building Renovation: Solutions to Save Energy<\/em><\/strong><em>.<\/em><\/a><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Addressing the <strong>renovation of these buildings<\/strong> is not simply about updating their cosmetic appearance; it is about providing them with a new, intelligent architectural envelope capable of managing climatic loads and ensuring long-term durability.[\/vc_column_text]<style>.ld_spacer_6aa7742e9d983{height:15px;}<\/style>\n<div class=\"ld-empty-space ld_spacer_6aa7742e9d983\"><\/div>[vc_single_image image=&#8221;247249&#8243; img_size=&#8221;large&#8221; alignment=&#8221;center&#8221;]<style>.ld_spacer_6aa7742e9da13{height:15px;}<\/style>\n<div class=\"ld-empty-space ld_spacer_6aa7742e9da13\"><\/div>[\/vc_column][\/vc_row][vc_row][vc_column column_content_align=&#8221;justify-content-center&#8221;]<style>.ld_spacer_6aa7742e9da9d{height:22px;}<\/style>\n<div class=\"ld-empty-space ld_spacer_6aa7742e9da9d\"><\/div>[vc_column_text]<\/p>\n<h2>How Does Extreme Weather Affect Building Fa\u00e7ades?<\/h2>\n<p>[\/vc_column_text]<style>.ld_spacer_6aa7742e9db23{height:22px;}<\/style>\n<div class=\"ld-empty-space ld_spacer_6aa7742e9db23\"><\/div>[vc_column_text]The fa\u00e7ade is a building&#8217;s <strong>first line of defense<\/strong>. When the building envelope lacks a multilayer design and continuous insulation, exposure to severe weather degrades exterior materials and ultimately compromises both <strong>indoor thermal comfort<\/strong> and <strong>structural safety<\/strong>.<\/p>\n<table style=\"height: 67px;\" width=\"1090\">\n<tbody>\n<tr>\n<td width=\"535\">\ud83d\udd17 <em>To explore the consequences of a poorly insulated building envelope in greater depth and learn how to identify early signs of deterioration, read our analysis:\u00a0<\/em><a href=\"https:\/\/faveker.com\/en\/blog\/what-deficiencies-can-a-poorly-insulated-facade-have\/\"><strong><em>What Defects Can a Poorly Insulated Fa\u00e7ade Develop?<\/em><\/strong><\/a><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Below, we assess the main <strong>climatic stressors<\/strong> affecting contemporary buildings:[\/vc_column_text]<style>.ld_spacer_6aa7742e9dba6{height:42px;}<\/style>\n<div class=\"ld-empty-space ld_spacer_6aa7742e9dba6\"><\/div>[vc_column_text]<\/p>\n<h3>1. Thermal Stress: Extreme Heat and Cold<\/h3>\n<p>[\/vc_column_text]<style>.ld_spacer_6aa7742e9dc28{height:42px;}<\/style>\n<div class=\"ld-empty-space ld_spacer_6aa7742e9dc28\"><\/div>[vc_column_text]Sudden temperature fluctuations cause traditional materials to expand and contract. Over time, this mechanical stress leads to microcracks and fractures that compromise <strong>weather-tightness<\/strong>. Furthermore, an uninsulated building envelope transfers outdoor temperatures directly indoors, making spaces difficult to cool in summer and heat in winter.<\/p>\n<table style=\"height: 31px;\" width=\"1036\">\n<tbody>\n<tr>\n<td width=\"525\">\ud83d\udd17 The main cause of thermal shock is heat loss through structural discontinuities. Discover how to identify and address this issue in our post:\u00a0<a href=\"https:\/\/faveker.com\/en\/blog\/thermal-bridges-what-they-are-and-how-to-solve-them\/\"><strong>Thermal Bridges in Buildings: What Are They and How Can They Be Resolved?<\/strong><\/a><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>[\/vc_column_text]<style>.ld_spacer_6aa7742e9dcb6{height:42px;}<\/style>\n<div class=\"ld-empty-space ld_spacer_6aa7742e9dcb6\"><\/div>[vc_column_text]<\/p>\n<h3>2. Torrential Rainfall and Persistent Moisture<\/h3>\n<p>[\/vc_column_text]<style>.ld_spacer_6aa7742e9dd5c{height:42px;}<\/style>\n<div class=\"ld-empty-space ld_spacer_6aa7742e9dd5c\"><\/div>[vc_column_text]<strong>High-intensity rainfall<\/strong> puts the <strong>waterproofing performance<\/strong> of exterior walls to the test. When water penetrates through pores or cracks, it causes moisture infiltration, promotes indoor mold growth and degrades internal structural components over time.<\/p>\n<table style=\"height: 81px;\" width=\"1158\">\n<tbody>\n<tr>\n<td width=\"502\">\ud83d\udd17 <em>To ensure maximum weather-tightness without compromising system ventilation, the geometric design of external panels plays a key role. Discover the technical details in:\u00a0<\/em><a href=\"https:\/\/faveker.com\/en\/blog\/ceramic-tongue-and-groove-ventilated-facades-humid-areas\/\"><strong><em>What Does Ceramic Tongue-and-Groove Profiling Bring to Ventilated Fa\u00e7ades in Humid Areas?<\/em><\/strong><\/a><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>[\/vc_column_text]<style>.ld_spacer_6aa7742e9ddef{height:42px;}<\/style>\n<div class=\"ld-empty-space ld_spacer_6aa7742e9ddef\"><\/div>[vc_column_text]<\/p>\n<h3>3. The Coastal Challenge: Salt Air and Marine Corrosion<\/h3>\n<p>[\/vc_column_text]<style>.ld_spacer_6aa7742e9de73{height:42px;}<\/style>\n<div class=\"ld-empty-space ld_spacer_6aa7742e9de73\"><\/div>[vc_column_text]<strong>Coastal areas<\/strong> have a particularly harsh microclimate characterized by <strong>high relative humidity<\/strong> and airborne marine chlorides (salt spray). This combination accelerates the degradation of porous cladding and unsuitable fixings, requiring constant repairs and maintenance.<\/p>\n<table style=\"height: 81px;\" width=\"1126\">\n<tbody>\n<tr>\n<td width=\"538\">\ud83d\udd17 <em>If you are managing an architectural or heritage project located by the sea or exposed to harsh saline conditions, explore our dedicated study:\u00a0<\/em><a href=\"https:\/\/faveker.com\/en\/blog\/heatwaves-coastal-corrosion-protect-facade\/\"><strong><em>Heatwaves and Coastal Corrosion: How to Protect Your Building\u2019s Fa\u00e7ade from Extreme Weather<\/em><\/strong><em>.<\/em><\/a><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>[\/vc_column_text]<style>.ld_spacer_6aa7742e9df10{height:42px;}<\/style>\n<div class=\"ld-empty-space ld_spacer_6aa7742e9df10\"><\/div>[vc_column_text]<\/p>\n<h3>4. Freeze-Thaw Cycles in Continental and Mountain Climates<\/h3>\n<p>[\/vc_column_text]<style>.ld_spacer_6aa7742e9dfea{height:42px;}<\/style>\n<div class=\"ld-empty-space ld_spacer_6aa7742e9dfea\"><\/div>[vc_column_text]Inland regions with significant winter temperature swings and high-altitude mountain areas require specifiers to mitigate <strong>frost-related damage<\/strong>. If an exterior material absorbs water and ambient temperatures drop below 0\u00b0C, the freezing water expands within the pores, causing cracking, spalling and surface destruction. In these environments, specifying <strong>high-density extruded ceramic solutions with virtually zero water absorption<\/strong> is essential.[\/vc_column_text]<style>.ld_spacer_6aa7742e9e0b9{height:42px;}<\/style>\n<div class=\"ld-empty-space ld_spacer_6aa7742e9e0b9\"><\/div>[vc_column_text]<\/p>\n<h3>5. Urban Heat Islands and High Pollution Levels<\/h3>\n<p>[\/vc_column_text]<style>.ld_spacer_6aa7742e9e17d{height:42px;}<\/style>\n<div class=\"ld-empty-space ld_spacer_6aa7742e9e17d\"><\/div>[vc_column_text]In densely built <strong>urban centers<\/strong>, s<strong>olar absorption by pavement and building fa\u00e7ades<\/strong> creates the \u201curban heat island\u201d effect, elevating local temperatures significantly above surrounding rural areas. This is compounded by <strong>airborne pollution<\/strong>, which quickly soils and degrades exterior finishes. Urban renovation projects require highly durable, non-porous surfaces with high solar reflectance that promote natural self-cleaning via rainwater.[\/vc_column_text]<style>.ld_spacer_6aa7742e9e235{height:42px;}<\/style>\n<div class=\"ld-empty-space ld_spacer_6aa7742e9e235\"><\/div>[vc_row_inner content_placement=&#8221;middle&#8221;][vc_column_inner responsive_align=&#8221;text-lg-center&#8221;][\/vc_column_inner][\/vc_row_inner][vc_column_text]<\/p>\n<h2>Safety and Regulations: What Today\u2019s Specifier Requires<\/h2>\n<p>[\/vc_column_text]<style>.ld_spacer_6aa7742e9e2e7{height:42px;}<\/style>\n<div class=\"ld-empty-space ld_spacer_6aa7742e9e2e7\"><\/div>[vc_column_text]Faced with these <strong>climatic challenges<\/strong>, architects, project management teams and developers require <strong>total technical certainty<\/strong>. The selection of a building envelope system must strictly comply with modern requirements for health, energy efficiency and acoustic protection.<\/p>\n<table style=\"height: 79px;\" width=\"1046\">\n<tbody>\n<tr>\n<td width=\"502\">\ud83d\udd17 Constant regulatory updates are establishing new design standards and requiring insulation solutions to adapt to modern performance metrics. Discover all the details in our technical analysis:\u00a0<a href=\"https:\/\/faveker.com\/en\/blog\/new-cte-key-changes\/\"><strong>New CTE: Key Changes and Requirements for Fa\u00e7ades<\/strong>.<\/a><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Furthermore, under the current framework of the <strong>Spanish Building Technical Code (CTE)<\/strong>, <strong>passive fire safety<\/strong> has become a critical requirement when specifying fa\u00e7ade systems\u2014particularly for high-rise buildings and residential renovations. Professionals require comprehensive solutions based on preventive criteria that actively minimize the risk of external fire spread.<\/p>\n<table style=\"height: 74px;\" width=\"1049\">\n<tbody>\n<tr>\n<td width=\"534\">\ud83d\udd17 Architectural design is the primary line of defense against fire. We assess key protection and compartmentation criteria in: <a href=\"https:\/\/faveker.com\/en\/blog\/fire-prevention-in-building-design\/\"><strong>Fire Prevention in Building Design: Criteria and Solutions<\/strong>.<\/a><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>The vulnerability demonstrated by certain conventional construction systems and combustible cladding materials in large-scale fires has transformed industry standards. Today, safe architecture relies on <strong>completely non-combustible materials<\/strong> (Class A1) and systems that act as continuous thermal shields.<\/p>\n<table style=\"height: 76px;\" width=\"1054\">\n<tbody>\n<tr>\n<td width=\"534\">\ud83d\udd17 We analyze the importance of material safety through real-world construction experience in our article:\u00a0<a href=\"https:\/\/faveker.com\/en\/blog\/campanar-building-renovation-ceramic-ventilated-facade\/\"><strong>Case Study and Safety: The Renovation of the Campanar Building with a Ceramic Ventilated Fa\u00e7ade<\/strong>.<\/a><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>[\/vc_column_text]<style>.ld_spacer_6aa7742e9e3b5{height:42px;}<\/style>\n<div class=\"ld-empty-space ld_spacer_6aa7742e9e3b5\"><\/div>[vc_column_text]<\/p>\n<h2>The Ultimate Solution: Renovation with a Ceramic Ventilated Fa\u00e7ade<\/h2>\n<p>[\/vc_column_text]<style>.ld_spacer_6aa7742e9e483{height:42px;}<\/style>\n<div class=\"ld-empty-space ld_spacer_6aa7742e9e483\"><\/div>[vc_column_text]In response to the limitations of conventional bonded render systems, modern architecture is turning to the technical versatility of <strong>ventilated fa\u00e7ades<\/strong>. This multilayer system separates the external cladding from the load-bearing wall, creating an intermediate cavity that houses continuous thermal insulation alongside an active air gap.<\/p>\n<p>The heating of air within this cavity triggers the <strong>chimney effect<\/strong>: warm air rises and exits through the top of the envelope, facilitating continuous airflow in summer while keeping the internal structure dry and protected from condensation year-round.<\/p>\n<p>By incorporating <strong>FAVEKER\u00ae extruded ceramic<\/strong> panels as external cladding, the building gains an exceptionally strong mechanical shield that remains immune to UV radiation and inert to chemical and saline agents.<\/p>\n<table style=\"height: 57px;\" width=\"1018\">\n<tbody>\n<tr>\n<td width=\"557\">\ud83d\udd17 <em>Discover the mechanical properties and structural advantages of this high-performance material in our technical article:\u00a0<\/em><a href=\"https:\/\/faveker.com\/en\/blog\/why-choose-porcelain-tile-outdoor-facade\/\"><strong><em>Why Choose Porcelain Stoneware for an Exterior Fa\u00e7ade Cladding?<\/em><\/strong><\/a><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>[\/vc_column_text]<style>.ld_spacer_6aa7742e9e510{height:42px;}<\/style>\n<div class=\"ld-empty-space ld_spacer_6aa7742e9e510\"><\/div>[vc_single_image image=&#8221;247323&#8243; img_size=&#8221;large&#8221; alignment=&#8221;center&#8221;]<style>.ld_spacer_6aa7742e9e58d{height:42px;}<\/style>\n<div class=\"ld-empty-space ld_spacer_6aa7742e9e58d\"><\/div>[vc_row_inner content_placement=&#8221;middle&#8221;][vc_column_inner responsive_align=&#8221;text-lg-center&#8221;][\/vc_column_inner][\/vc_row_inner][vc_column_text]<\/p>\n<h2>Thermal Mass and Inertia: Stabilizing Indoor Temperatures<\/h2>\n<p>[\/vc_column_text]<style>.ld_spacer_6aa7742e9e651{height:42px;}<\/style>\n<div class=\"ld-empty-space ld_spacer_6aa7742e9e651\"><\/div>[vc_column_text]The <strong>energy performance of a ventilated fa\u00e7ade<\/strong> can be significantly enhanced by choosing high-density cladding materials. Extruded ceramic features a high specific heat capacity, providing excellent thermal inertia that absorbs and releases heat very gradually.<\/p>\n<p>This <strong>thermal mass<\/strong> acts as a natural buffer against extreme temperature fluctuations. By delaying heat transfer into the building during peak solar exposure, it helps maintain stable, comfortable indoor temperatures while substantially reducing HVAC energy demands.<\/p>\n<table style=\"height: 59px;\" width=\"1045\">\n<tbody>\n<tr>\n<td width=\"534\">\ud83d\udd17 <em>Discover the physics behind this phenomenon and how to apply them to your project&#8217;s energy calculations in: <\/em><a href=\"https:\/\/faveker.com\/en\/blog\/thermal-inertia-energy-savings-buildings\/\"><strong><em>Why Does Thermal Inertia Contribute to Energy Savings?<\/em><\/strong><\/a><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>[\/vc_column_text]<style>.ld_spacer_6aa7742e9e753{height:42px;}<\/style>\n<div class=\"ld-empty-space ld_spacer_6aa7742e9e753\"><\/div>[vc_column_text]<\/p>\n<h2>From an Unavoidable Expense to a Highly Profitable Investment<\/h2>\n<p>[\/vc_column_text]<style>.ld_spacer_6aa7742e9e822{height:42px;}<\/style>\n<div class=\"ld-empty-space ld_spacer_6aa7742e9e822\"><\/div>[vc_column_text]Proposing a comprehensive envelope renovation is often met with initial hesitation over upfront costs from homeowners&#8217; associations and property managers. However, installing a ventilated fa\u00e7ade is neither an arbitrary expense nor a simple maintenance chore\u2014it is a high-return property investment.<\/p>\n<p>Choosing extruded ceramic cladding delivers immediate, long-term benefits from day one:<\/p>\n<ul>\n<li><strong>Immediate property appreciation: <\/strong>Achieving a higher Energy Performance Certificate (EPC) rating automatically boosts the appraised market value of each unit in the building.<\/li>\n<li><strong>Minimal maintenance costs:\u00a0<\/strong>The extreme durability of extruded stoneware eliminates recurring expenses for repainting, crack repairs and damp-proofing treatments. It is an unalterable solution engineered to last a lifetime.<\/li>\n<li><strong>Measurable energy savings:\u00a0<\/strong>By dramatically cutting heating demand in winter and cooling needs in summer, property owners see tangible financial returns month after month on utility bills.<\/li>\n<\/ul>\n<table style=\"height: 67px;\" width=\"1113\">\n<tbody>\n<tr>\n<td width=\"521\">\ud83d\udd17 <em>To analyze these financial figures and understand their impact on property owners, read our report:\u00a0<\/em><a href=\"https:\/\/faveker.com\/en\/blog\/heating-savings-homeowners-association-ceramic-ventilated-facade-investment\/\"><strong><em>Expense or Investment? How Much Can a Homeowners\u2019 Association Really Save with a Ventilated Fa\u00e7ade?<\/em><\/strong><\/a><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>[\/vc_column_text]<style>.ld_spacer_6aa7742e9e908{height:42px;}<\/style>\n<div class=\"ld-empty-space ld_spacer_6aa7742e9e908\"><\/div>[vc_single_image image=&#8221;247335&#8243; img_size=&#8221;large&#8221; alignment=&#8221;center&#8221;]<style>.ld_spacer_6aa7742e9e9e3{height:42px;}<\/style>\n<div class=\"ld-empty-space ld_spacer_6aa7742e9e9e3\"><\/div>[vc_column_text]<\/p>\n<h2>Next Steps in Your Renovation Project with FAVEKER\u00ae<\/h2>\n<p>[\/vc_column_text]<style>.ld_spacer_6aa7742e9eae6{height:42px;}<\/style>\n<div class=\"ld-empty-space ld_spacer_6aa7742e9eae6\"><\/div>[vc_column_text]Protecting a building against the progressive impacts of extreme weather is a vital step toward extending its service life and safeguarding occupant well-being. Achieving a successful renovation requires specialized technical support from the earliest design stages.<\/p>\n<p>At <strong>FAVEKER\u00ae<\/strong>, we equip architects, installers and developers with a suite of technical tools designed for informed decision-making:<\/p>\n<ul>\n<li><strong>Feasibility assessment:\u00a0<\/strong>Want to verify whether your existing building structure is suitable for a ventilated fa\u00e7ade system?<\/li>\n<\/ul>\n<table style=\"height: 86px;\" width=\"975\">\n<tbody>\n<tr>\n<td width=\"518\">\ud83d\udd17 <em>Check out our practical guide:\u00a0<\/em><a href=\"https:\/\/faveker.com\/en\/blog\/feasibility-guide-building-renovation-with-ventilated-facade\/\"><strong><em>Feasibility Guide: How to Determine Whether a Building Can Be Renovated with a Ventilated Fa\u00e7ade<\/em><\/strong><\/a><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<ul>\n<li><strong>Construction methodology and installation:\u00a0<\/strong>Are you a technical professional looking for an in-depth breakdown of every installation phase?<\/li>\n<\/ul>\n<table style=\"height: 56px;\" width=\"977\">\n<tbody>\n<tr>\n<td width=\"518\">\ud83d\udd17 <em>Access our reference manual:\u00a0<\/em><a href=\"https:\/\/faveker.com\/en\/blog\/definitive-guide-to-rehabilitation-with-ventilated-facades\/\"><strong><em>Renovation with a Ventilated Fa\u00e7ade: The Ultimate Guide to Safe Planning<\/em><\/strong><em>.<\/em><\/a><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>The climate is changing, and architecture must adapt.<\/p>\n<table style=\"height: 68px;\" width=\"979\">\n<tbody>\n<tr>\n<td width=\"559\"><strong>Contact the <\/strong><a href=\"https:\/\/faveker.com\/en\/technical-office\/\"><strong>FAVEKER\u00ae Technical Office<\/strong><\/a> for personalized advice on developing advanced ceramic solutions and driving sustainable, safe and energy-efficient construction projects.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>[\/vc_column_text][\/vc_column][\/vc_row]<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Extreme weather is accelerating the deterioration of buildings and putting fa\u00e7ades designed for milder conditions to the test. Discover how refurbishment with ceramic ventilated fa\u00e7ades can improve protection, energy efficiency, safety, and property value in the face of heat, humidity, salt air, and other climate-related phenomena.<\/p>\n","protected":false},"author":2,"featured_media":16682,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_lmt_disableupdate":"yes","_lmt_disable":"","wds_primary_category":24,"footnotes":""},"categories":[68],"tags":[],"class_list":["post-14421","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-everything-for-facades"],"acf":[],"modified_by":"faveker","_links":{"self":[{"href":"https:\/\/faveker.com\/en\/wp-json\/wp\/v2\/posts\/14421","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/faveker.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/faveker.com\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/faveker.com\/en\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/faveker.com\/en\/wp-json\/wp\/v2\/comments?post=14421"}],"version-history":[{"count":0,"href":"https:\/\/faveker.com\/en\/wp-json\/wp\/v2\/posts\/14421\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/faveker.com\/en\/wp-json\/wp\/v2\/media\/16682"}],"wp:attachment":[{"href":"https:\/\/faveker.com\/en\/wp-json\/wp\/v2\/media?parent=14421"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/faveker.com\/en\/wp-json\/wp\/v2\/categories?post=14421"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/faveker.com\/en\/wp-json\/wp\/v2\/tags?post=14421"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}